SOURCE: Coleman Powermate 6250 only runs with choke closed/air restricted
A call to Elliott Small Engine solved my problem - Oil Guard. I had checked the oil and it was just a little low but seemed well within the normal range. I was told to add more, bringing it just over the Full mark. It seems that the low oil protection system is very sensitive and shuts down the engine even when the oil is withing 1/8" of the mark. I added about 2-3 oz of oil and no more problems
SOURCE: Honda generator ei3000. Will run only a few mins
Tank filter not blocked? (Take tap off tank) Enough oil in motor? Try overfilling it slightly
SOURCE: Poulan PP446T Pole Saw. Will run only if choke is
It is running lean. There is an air leak somewhere allowing to much air into the cylinder or crankcase. Continuing to operate lean may cause failure. If fuel delivery lines have no pin holes or cracks probably time for some professional help (pressure tests). Remove clean and reinstall the muffler (carbon fouling can also cause this). If the saw cannot exhale, it cannot inhale. HTH
Lou
SOURCE: Starts and idles will not run above idle unless
Hi,
Have you tried adjusting the carb? There should be two screws on the carb (hi & Low) turn the hi screw completely until it stops and then start the unit. Let it warm up and then begin to back the screw out until it starts to run smoothly but strong. Once you have it running then put it in full run position (choke) and you should be good.
Good luck!
SOURCE: i have a coleman powermate premium plus 6250
if you are running the engine at full CHOKE, then it is flooding the engine, but if you meant off full choke, then the carb is still stopped up. Try soaking in carb cleaner overnight after removing jet & all rubber goods. HOPE THIS HELPS.